EasyManua.ls Logo

Simrad ST90 - Turning on the ST90 for the First Time; Verifying that Operational Power Is Correct

Simrad ST90
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
276
442703/B
TurningontheST90forthersttime
Topics
Verifyingthatoperationalpoweriscorrect,page276
TurningontheProcessorUnitforthersttime,page277
SettinguptheOperatingPanel(Mk2),page278
TurningontheTransceiverUnitforthersttime,page281
TurningontheST90toPassivemode,page282
MeasuringtheBITEnoisewiththetransducerdisconnectedfromtheTransceiverUnit,
page283
MeasuringtheB-ScannoisewiththetransducerdisconnectedfromtheTransceiver
Unit,page285
ConnectingthetransducercablestotheTransceiverUnit,page287
TurningontheentireST90systemforthersttime,page289
TurningontheST90,page294
Verifyingthatoperationalpoweriscorrect
TheST90operatesonACpowerfromthevessel’smainssupply.BeforeyouapplyAC
powertoanyST90unit,youmustverifythatthevoltageiscorrect.
Prerequisites
Beforeyoucandothistask,thefollowingprerequisitesmustbemet:
AllST90hardwareunitshavebeeninstalledaccordingtotherelevantinstructions.
Allsystemcableshavebeeninstalled.
Alloperatingpowerisavailable.
Allrelevantpersonnel(shipselectrician)andtools(forexampleavoltmeter)are
available.
Procedure
1ForeachST90unitthatoperatesonACmains:
aIfnecessary,measurethevoltageinthemainsoutlet.
bMakesurethattherelevantST90unitcanoperateonthepowerprovided.
2Makesurethateachcircuitbreakeronthepowercircuitcanhandletheloadwhen
theST90isturnedon.