EasyManua.ls Logo

Simrad ST90 - Topside Cables with Optional Operating Panel Mk1

Simrad ST90
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
442703/B
167
Cable
Type
From/ToMinimumrequirements
VideocableFromProcessorUnittodisplay
C9
Thisisacommercialcable.Thedisplaycableisoftenphysicallyattachedtothedisplay,
andterminatedinthe“computerend”withamaleconnector.Ifthecableisnotattached,
itisnormallyprovidedwiththedisplay.
C10
Notused(Thiscableisusedwithoptional
OperatingPanelMk1.)
C11
Notused
C12
EthernetcableFromProcessorUnitto
OperatingPanel
CAT5-ESTP(ShieldedTwisted
Pair)
SerialcableFromProcessorUnittoexternal
device(s)
2x4x0.5mm
2
C13
IfyouwishtouseRS-422orRS-485serialcommunication,useacablewithtwistedpairs.
C14
EthernetcableFromProcessorUnittolocal
areanetwork(LAN)
CAT5-ESTP(ShieldedTwisted
Pair)
C15
Notused(Thiscableisusedwithoptional
OperatingPanelMk1.)
C16
Notused(Thiscableisusedwithoptional
OperatingPanelMk1.)
C17
Notused(Thiscableisusedwithoptional
OperatingPanelMk1.)
C18-19
Notused
Relatedtopics
ListofST90cables,page166
Topsidecableplan,page161
TopsidecableplanwithoptionalOperatingPanelMk1,page163
Sonarroomcableplan,page164
InstallingtheST90cables,page171
TopsidecableswithoptionalOperatingPanelMk1
Cable
Type
From/ToMinimumrequirements
ACpowercableFromOperatingPanelPower
Supplytouninterruptiblepower
supply(UPS)
C4
BothpowercablesusedwiththeOperatingPanelPowerSupplyarephysicallyattachedto
theunit.
C10
NotusedFromOperatingPaneltovessel
ground
1x6mm
2
Cablelayoutandinterconnections

Table of Contents

Other manuals for Simrad ST90