266
442703/B
3MakesurethateachcablehasbeeninstalledasspeciedintheCablelayoutand
interconnectionschapter.
4Toapplypower,closethecircuitbreakerforthe3-phaseACvoltage.
5Measurethe3-phaseACmainsvoltageonterminalblockE301.
6AdjustthereleasecurrentontheMotorProtectingSwitch(S301)accordingtothe
3-phasevoltageinuse.
•230V AC:10A(Maximum)
•380/440V AC:6.5A
Relatedtopics
Settingtoworksummary,page242
Startingupthehullunit,page257
Hullunitdescription,page257
Hullunitfamiliarization,page260
MotorControlUnitfamiliarization,page261
InitialsafetycheckoftheMotorControlUnit,page262
Checkingthehostingmotor’s3-phaseACconnections,page263
Connectingthe3-phaseACpowertotheMotorControlUnit,page265
Ventingthetransducershaftsleeve,page266
Checkingthe3-phaseconnectionforcorrectrotation,page268
CheckingtheoperationoftheHoistingandLoweringcontactors,page270
Checkingthetransducerloweringandhoistingfunctionality,page273
Ventingthetransducershaftsleeve
Thehullunitislubricatedasapartoftheproductionprocess,andthusprovidedfully
lubricatedwhendeliveredtothevessel.Additionallubricationofthehullunitmustonly
takeplacewhenrequired.Evenwhenthetransducershaftsleeveisfullylubricated,
smallairpocketsmayexpandiftheST90isusedinaverywarmclimate.Insomecases,
theseairpocketshavemadeitdifculttolowerandhoistthetransducer.
Prerequisites
Thefollowingspecictoolisrequiredforthistask:
•Adjustablespanner(Wrench)
SimradST90InstallationManual