EasyManua.ls Logo

Simrad ST90 - Initial Safety Check of the Motor Control Unit

Simrad ST90
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
262
442703/B
Relatedtopics
Settingtoworksummary,page242
Startingupthehullunit,page257
Hullunitdescription,page257
Hullunitfamiliarization,page260
MotorControlUnitfamiliarization,page261
InitialsafetycheckoftheMotorControlUnit,page262
Checkingthehostingmotor’s3-phaseACconnections,page263
Connectingthe3-phaseACpowertotheMotorControlUnit,page265
Ventingthetransducershaftsleeve,page266
Checkingthe3-phaseconnectionforcorrectrotation,page268
CheckingtheoperationoftheHoistingandLoweringcontactors,page270
Checkingthetransducerloweringandhoistingfunctionality,page273
InitialsafetycheckoftheMotorControlUnit
SafetyisalwaysimportantwhenworkingontheHullUnitandtheMotorControlUnit.
Highvoltagesareused.TheinitialsettingsmustbeveriedbeforetheHullUnitcanbe
startedforthersttime.
Prerequisites
TheST90isturnedoff.
Thecircuitbreakerforthe3-phaseACpowerisdisengaged.
Allcableconnectionsaremade.
Youmustbeequippedwithastandardsetoftools.Thistoolsetmustcomprise
thenormaltoolsforelectronictesting,aswellasthenecessarytoolsforrelevant
disassembly/assemblyofpartsfortestaccess.Eachtoolmustbeprovidedinvarious
sizes.Werecommendthatalltoolsaredemagnetizedtoprotectyourequipment.
Context
Highvoltagesareused.Thisequipmentmustbeservicedonlybyqualiedpersonnel
familiarwithhigh-voltageequipmentandthepotentialhazardsinvolved.Failureto
observethisprecautioncouldresultinbodilyinjury.
Procedure
1Makesurethatthe3-phaseACpowerisdisconnected,andthatthecircuitbreakers
aredisengagedintheship’sfusebox.
2UseaspannertoopenthedoorontheMotorControlUnit.
3LocatetheMotorProtectingSwitch(S301).CheckthattheswitchisinpositionOFF.
4LocateHoist/LowerSwitch(S302).CheckthattheswitchisinpositionSTOP.