394
442703/B
•Powerrequirements:Notapplicable.ThisunitisnotpoweredbyACmains.
OperatingPanelPowerSupply
•Makeandmodel:ST90OperatingPanelPowerSupply
•Voltagerequirement:115/230V AC,47to63Hz,singlephase,nominal
•Maximumvoltagedeviation:15%
•Maximumtransient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:10V A(Approximately)
ThepowersupplyisconnectedtoadedicatedsocketontherearsideoftheProcessor
Unit.
OperatingPanelpowerrequirements(Mk2)
•Makeandmodel:ST90OperatingPanelMk2
•Voltagerequirement:115/230V AC,47to63Hz,singlephase,nominal
•Maximumvoltagedeviation:15%
•Maximumtransient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:10W(Approximately)
Relatedtopics
Technicalspecications,page388
TransceiverUnitpowerspecications
•Makeandmodel:ST90TransceiverUnit
•Voltagerequirement:230V AC,47to63Hz,singlephase,nominal
•Maximumvoltagedeviation:15%
•Maximumtransient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:600V A(Approximately)
Relatedtopics
Technicalspecications,page388
HullUnitpowerrequirements
•Make:ST90HullUnit
•Model:Allmodels
•Voltagerequirement:230/380/440V AC,47to63Hz,3-phase
SimradST90InstallationManual