394
442703/B
Powerrequirements:Notapplicable.ThisunitisnotpoweredbyACmains.
OperatingPanelPowerSupply
Makeandmodel:ST90OperatingPanelPowerSupply
Voltagerequirement:115/230V AC,47to63Hz,singlephase,nominal
Maximumvoltagedeviation:15%
Maximumtransient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:10V A(Approximately)
ThepowersupplyisconnectedtoadedicatedsocketontherearsideoftheProcessor
Unit.
OperatingPanelpowerrequirements(Mk2)
Makeandmodel:ST90OperatingPanelMk2
Voltagerequirement:115/230V AC,47to63Hz,singlephase,nominal
Maximumvoltagedeviation:15%
Maximumtransient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:10W(Approximately)
Relatedtopics
Technicalspecications,page388
TransceiverUnitpowerspecications
Makeandmodel:ST90TransceiverUnit
Voltagerequirement:230V AC,47to63Hz,singlephase,nominal
Maximumvoltagedeviation:15%
Maximumtransient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:600V A(Approximately)
Relatedtopics
Technicalspecications,page388
HullUnitpowerrequirements
Make:ST90HullUnit
Model:Allmodels
Voltagerequirement:230/380/440V AC,47to63Hz,3-phase