442703/B
395
Maximumvoltagedeviation(230V AC):15%
Maximumvoltagedeviation(380/440V AC):340-485V AC
Maximumtransient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:3000V A(Approximately)
Circuitbreakerrequirements:
Whenthehoistmotorstarts,itdrawsalotofpower.Itisthereforeimportantthatthe
electricsupplyisequippedwithasuitablecircuitbreaker.Thecircuitbreakermust
beabletowithstandthelargestartingcurrent.Werecommendusingcircuitbreaker
withoneofthefollowingratings:
16D
20C
Thecircuitbreakerislabeledwiththeratedcurrentinamperes,butexcludingthe
unitsymbol,A.Instead,theamperegureisprecededbyaletter,B,C,orD,which
indicatestheinstantaneoustrippingcurrent.Thatistheminimumvalueofcurrent
thatcausesthecircuitbreakertotripwithoutintentionaltimedelay.Ingeneralterms,
theCtypecircuitbreakerwillwithstand10timestheratedcurrentforashortperiod
oftime.TheDtypecircuitbreakerwillwithstand20timestheratedcurrent.For
moreinformation,seestandardBSEN60898.