442703/B
267
Context
Thetransducershaftsleeveisventedasapart
ofthe"settingtowork"processafterinstallation.
Theprocedurecanberepeatedifthemovements
ofthetransducershaftareperceivedasslow.
Procedure
1Locatethepressurereleaseplug.
2Openthepressurereleaseplugslightlytoallowpressurizedairtoescape.
3Closethepressurereleaseplugrmly.
Relatedtopics
Settingtoworksummary,page242
Startingupthehullunit,page257
Hullunitdescription,page257
Hullunitfamiliarization,page260
MotorControlUnitfamiliarization,page261
InitialsafetycheckoftheMotorControlUnit,page262
Checkingthehostingmotor’s3-phaseACconnections,page263
Connectingthe3-phaseACpowertotheMotorControlUnit,page265
Ventingthetransducershaftsleeve,page266
Checkingthe3-phaseconnectionforcorrectrotation,page268
CheckingtheoperationoftheHoistingandLoweringcontactors,page270
Checkingthetransducerloweringandhoistingfunctionality,page273
Settingtowork