EasyManua.ls Logo

Stoll CMS 520 C+ - Page 106

Default Icon
562 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
106
3 Producing with the knitting machine
Production
1. Call up the "Service" window in the "Main menu".
2. Call up the "Running time control" window in the "Service" window.
3. Call up "Additional function keys".
4. Call up the "Catalog running time data" wind
ow.
5. Select the desired path
with the "Current folder selection" key.
6. Select file.
7. Select action (load, save, delete).
8. If an additional prompt appears
, tap the "1" k
ey to confirm.
- or -
Press the key "0" to cancel.
Display o
f the remaining
running
time
Display of the expected remaining running time (net) of a pattern (sequence,
sequence element, order).
Depending on the file you selected in the
"Running time control" window, the
title of the window changes.
For a sequence, the title is "Running
time data sequence".
For a single pattern or a sequence element, the title is "Running
time data
pattern".
Running time data sequence (Running time data pattern) window
"Running time data sequence" ("Running time data pattern") window
Data in the Run ning time data s equence windo w or in the R unning time d ata pattern window
Data in the "Running time data sequence" window or in the "Running time data pattern"
window
Entry
Meaning
Name
Name of sequence, sequence element or pattern
Remaining running time
Display of the remaining running time
(average net remaining running time x fabrics which are still
to
be kn
itted = remaining running time).
Format: Minutes, seconds
End time
Display of the end time. Format: Date, time
Possible only after a run-through
Running time piece
The shortest and the longest running times are displayed to
facilitate the evaluation of th
e expected remaining running
time.

Table of Contents