204
4 Adjusting knitting machine
Advanced adjustments
4. Compare the displayed values with the values on the machine data sheet.
If necessary, correct the values on the machine data sheet (
see the "Copy
Mc" description [201]).
5. Switch back to the pre
vious window.
6. Call up the "Needle bed parameters" windo
w.
7. Compare the displayed values with the value
s on the machine data sheet.
If necessary, correct the values on the machine data sheet.
8. Switch back to the pre
vious window.
9. Call up the "NPK values" window.
10. Compare the displayed values with the value
s on the machine data sheet.
If necessary, correct the values on the machine data sheet.
11. Switch back to the pre
vious window.
12. Call up the "Needle selection" window.
13. Compare the displayed values with the value
s on the machine data sheet.
If necessary, correct the values on the machine data sheet.
14. Call up "Main menu".
Carry out the reference run 1. If the racking device is not in the hom
e position, cast-off the stitches of a
needle bed.
2. Call up the "Service" menu.
3. Call up the "Reference r
uns" windo
w.
4. The reference data is determined at the left or right end of the need
le bed.
If the carriage is located in the left half of the needle bed,
tap the "SR!<"
key.
- or -
➜ If the carriage is located in the righ
t half of the needle bed, tap the "SR!>"
key.
5. Start the machine with the engaging rod.
Th
e carriage assembly carries out a reference run and stops as soon
as
it has determined the reference data. The engaging rod falls down.
6. The message "Reference run complete" is
displayed on the touch screen.
Reference run with older machines (before August 2013):
The reference data is determined at the center of th
e needle
bed.
The carriage moves automatically in both directions
During the reference run, the carriage can move independently
in
to bot
h directions.
The carriage stops automatically as soon as the reference data
is determi
ned. The engaging rod falls down.