X35 Monitor System Settings
4.22
Figure 4.26 - Fluctuating RPM Alarm
Figure 4.27 - Pack Master Incorrect Rate Alarm
Figure 4.28 - Scale Weight Difference Alarm
40. Fluctuating RPM - indicates that the granular
tank shaft rpm is fluctuating outside an
acceptable range.
a. Select the Threshold button to set a
percentage value that will be used to
calculate the upper and lower RPM limits.
Refer to Section
12 - Troubleshooting.
41. Pack Master Incorrect Rate - indicates that
the
actual Pack Master value is higher or lower
than the acceptable range.
a. Select the Threshold button to set a
percentage value that will be used to
calculate the upper and lower Pack Master
range limits.
42. Scale
Weight Difference (7000AS) - if
the
integrated scale link option is installed this
will alert if the measured (actual) weight is
changing at a different rate than the theoretical
weight change based on the cal factor. Refer to
Section 12 - Troubleshooting.
a. Scale - change which scale you are setting
the parameters
for.
b. Scale Alarm State - allows you to disable
individual
tank alarms rather than all of
them together.
c. Threshold - set the range to alarm outside
of.
d. Delay
- set how long the threshold needs
to be
exceeded before alarming. Defaulted
to 120 seconds (2 minutes).