Chapter 78 VoIP
OLT2406 User’s Guide
575
The second rule is between the | symbols. It has the PMG5318 dial a call when users dial a hash
symbol (#) followed by any number of digits from 0 to 9, an asterisks (*), any number of digits from 0
to 9, and the pound key twice (##).
The third rule comes after the second | symbol. It has the PMG5318 dial a call when users dial the
pound key (#) followed by any number of digits from 0 to 9, an asterisks (*), and any number of
digits from 0 to 9.
4 Set the slot containing the GPON card (slot 5) to use a GPON card and enable the slot.
5 Set the PON port’s register method for how the OLT registers ONTs connected to the port (A in this
example) and the PON port’s transceiver type (12 in this example). Then enable the PON port.
6 Configure the remote ONT’s provisioning and bandwidth group settings. (When you configure “remote
ONT” settings, the OLT configures the ONT with those settings.)
Slot 5, port 1, and sets the ONT’s ID to 1.
sn: serial number, 5A59584517035116 in this example.
pa: password, 44454641554C54000000 in this example.
Enable the ONT.
bwgroup: number 1 in this example.
usbwprofname: this example uses the 100m bandwidth profile for upstream traffic.
dsbwprofname: this example uses the 100m bandwidth profile for downstream traffic.
OLT2406# config
OLT2406(config)# voip-sip-profile sip
OLT2406(config-voip-sip-prof)# registrar 192.168.21.10
OLT2406(config-voip-sip-prof)# proxy-service-addr 192.168.21.10
OLT2406(config-voip-sip-prof)# host-part-uri 192.168.21.10
OLT2406(config-voip-sip-prof)# exit
OLT2406(config)# voip-common-profile common
OLT2406(config-com-prof)# exit
OLT2406(config)# voip-dial-plan dial
OLT2406(config-dial-plan-prof)# content 1 X*.X.#|#X.*.X.##|#X.*.X.
OLT2406(config-dial-plan-prof)# exit
OLT2406(config)# exit
OLT2406# config
OLT2406(config)# interface slot slot-5
OLT2406(config-slot)# cardtype gpon
OLT2406(config-slot)# no inactive
OLT2406(config-slot)# exit
OLT2406(config)# exit
OLT2406# config
OLT2406(config)# interface olt pon-5-1
OLT2406(config-olt)# register-method A
OLT2406(config-olt)# transceiver 12
OLT2406(config-olt)# no inactive
OLT2406(config-olt)# exit
OLT2406(config)# exit