Chapter 96 Remote ONT
OLT2406 User’s Guide
659
cfm-ma <ma-index> md-index
<md-index> format
<vid|string|integer> name <ma-
name> ccm-interval <0-7>
Creates an IEEE 802.1ag CFM Maintenance
Association (MA). The OLT creates the MA on
the remote ONT via OMCI request message.
ma-index: Maintenance association index.
md-index: Maintenance domain index.
vid|string|integer: Maintenance
association name format.
ma-name: Maintenance association name.
<0-7>: CCM interval.
0: CCM disable,
1:3.33 ms,
2: 10 ms,
3: 100 ms,
4: 1 sec,
5: 10 sec,
6: 1 min,
7: 10 min
C13
cfm-ma <ma-index> inactive
Disables the specified CFM Maintenance
association.
ma-index: Maintenance association index.
C13
cfm-md <md-index> format
<dns|mac|string> name <md-
name> level <0-7>
Creates an IEEE 802.1ag CFM Maintenance
Domain. The OLT creates the MD on the remote
ONT via OMCI request message.
md-index: Maintenance domain index.
dns|mac|string: Maintenance domain name
format.
md-name: Maintenance domain name.
0-7: Maintenance domain level.
C13
cfm-md <md-index> inactive
Disables the specified CFM Maintenance
domain.
ma-index: Maintenance domain index.
C13
clear-counter <cr>
Clears the counters for the remote ONT. E 13
exit
Exits from ONT configuration. C 13
full-bridge <enable|disable>
Enables full-bridge mode to allow the traffic of
all four UNI ports once any one of them is
configured.
C13
description <string>
Adds in a description for the ONT. C 13
inactive
Turns off the ONT. You can configure more
information such as a sequence number,
password, or model name.
C13
Table 352 Remote ONT Commands (continued)
COMMAND DESCRIPTION M P