Chapter 96 Remote ONT
OLT2406 User’s Guide
668
See Section 6.6 on page 87 for more information on how to upgrade ONTs to the latest firmware via the
OLT.
low-curr-thresh <0~79 | N/A>
Sets the lower laser bias current threshold.
Unit: mA
C13
low-rxpower-thresh <-127~0 |
N/A>
Sets the lower receive power threshold.
Unit: dBm
C13
low-temp <-40~100 | N/A>
Sets the lower temperature threshold.
Unit: celsius degree (°C)
C13
low-txpower-thresh <-15.3~6.5
| N/A>
Sets the lower transmit power threshold.
Unit: dBm
C13
low-volt-thresh <2.80~3.59 |
N/A>
Sets the lower power feed voltage threshold.
Unit: V
C13
up-curr-thresh <0~79 | N/A>
Sets the upper laser bias current threshold.
Unit: mA
C13
up-rxpower-thresh <-127~0 | N/
A>
Sets the upper receive power threshold.
Unit: dBm
C13
up-temp <-40~100 | N/A>
Sets the upper temperature threshold.
Unit: celsius degree (°C)
C13
up-txpower-thresh <-15.3~6.5 |
N/A>
Sets the upper transmit power threshold.
Unit: dBm
C13
up-volt-thresh <2.80~3.59 | N/
A>
Sets the upper power feed voltage threshold.
Unit: V
C13
exit
Leaves from the ONT alarm threshold
configuration profile.
C13
onu-model name <14 char> model-ID <0~8>
vendor-version <14 char> [software-
version <14 char>][card1 <1~254>...]
Creates an ONT model name, and configures
the following settings for the ONT:
•Model ID
• Vendor Version
• Software Version
•Card ID
C13
no onu-model all Returns all connected ONTs to the default
settings.
C13
no onu-model name <14 char> <cr> Returns the specified ONT to the default settings. C 13
no onu-model name <14 char> [card1
card2...]
Returns the card settings of the specified ONT to
default settings.
C13
onu-model help Provides more information about the specified
command.
C13
show onu-model <cr> Displays the following information of Zyxel ONT
products.
• Vendor Version
• Software Version
•Entity ID
E3
Table 352 Remote ONT Commands (continued)
COMMAND DESCRIPTION M P