Configure
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
41
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway Web GUI Users Guide
Configure LCP parameters in LCP Configuring table. This helps in deciding
whether the system initiates the LCP negotiation or just responds.
i. Enter the maximum echo value in Max Echo field.
This denotes the maximum number of unanswered LCP echo requests
sent before LCP decides that the peer is down. The value “0” implies that
the link will not be brought down on the basis of unanswered echo
requests. Default echo interval is 5 seconds.
ii. Enter the echo interval in Echo Interval field.
This denotes the interval between the LCP echo requests sent. “0” implies
that no echo requests are sent. The default value is 10 seconds.
Configure the PPP Timer configuration in Timer Configuring table.
i. Enter the restart timer in Restart Timer field to set the time period for
retransmission of LCP and NCP packets. The default value is 3 seconds.
ii. Enter the maximum number of pings before terminating to send packets in the
Max Terminate field.
This terminates request packets (Number of LCP or NCP) without
receiving a Terminate Ack before assuming that the peer is unable to
respond. The default value is 2 seconds.
iii. Enter the max configure value in Max Configure field.
Configure Request packets (Number of LCP or NCP) without receiving a
valid Configure Ack/NaK/Reject before assuming that the peer is unable
to respond. The default value is 10 seconds.
iv. Enter the max failure value in Max Failure field.
Configure NaK packets (Number of LCP or NCP) without receiving a
Configure Ack before assuming that configuration is not converging. The
default value is 5 seconds.
Click OK to save LCP and PPP Timers configuration or click Cancel to cancel the
operation.
8. After configuring the parameters, click Apply to save the PPP configuration or
click Cancel to cancel the operation.

Table of Contents

Other manuals for Alcatel-Lucent OmniAccess 5740

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniAccess 5740 and is the answer not in the manual?

Alcatel-Lucent OmniAccess 5740 Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniAccess 5740
CategoryGateway
LanguageEnglish

Related product manuals