Chapter 43: BSoD L2VPN
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 1085
L2VPN forwarding status: enable Current Status
L2VPN Primary Network Interface: gigabitEthernet 17/0 Active
L2VPN Secondary Network Interface: none
CM requirements: dut-filter esafe-ident
---------------- required required
CableMac Interfaces:
--------------------
1
Outer VLANid Q-tag type
------------ ----------
2-4000 single-qtag
L2VPNIDs in use
---------------
Cadant
Sample output for the show l2vpn l2vpnid command, where "Cadant" is the ID of the layer 2 VPN:
C4# show l2vpn l2vpnid Cadant
Downstream Forwarding Reported
Channel CM MAC State Capabilties VLANids SAID SFID-Dsid pairs
---------- -------------- ---------- ------------- --------- ----- ---------------
14/2 001c.ea27.4f2a enable esafe & dut 202 2 3-0, 4-0, 5-0
Sample output for the show l2vpn cl2vpnid <qtag> command, where 202 is the ID of the specific Q-tag:
C4# show l2vpn l2vpnid Cadant 202
DS=14/2 CM=001c.ea27.4f2a Forwarding=enable VLANids=202 SAID=2
Reported Capabilities= esafe & dut
SFID-Dsid pairs= 3-0, 4-0, 5-0
Upstream Packets 0 Bytes 0 Discards 0
Downstream Packets 0 Bytes 0 Discards
Sample output for the show l2vpn cm-mac <mac address> command, where 001c.ea27.4f2a is the specific MAC
address requested:
C4# show l2vpn cm-mac 001c.ea27.4f2a
DS=14/2 CM=001c.ea27.4f2a Forwarding=enable VLANids=202 SAID=2
Reported Capabilities= esafe & dut
SFID-Dsid pairs= 3-0, 4-0, 5-0