SCM access provides the IP connectivity to the CMTS SCM through the client cards. To disable the SCM access, use the [no] option.
Note: The following restrictions apply:
The SCM A, B and floating IP should all be in the same subnet.
The host that accesses the SCM via SCM access must NOT be in the same subnet of the floating IP
If SCM access is enabled and the time server IP is not in the same subnet as the SCM A, B or floating IP, you must set an ACL
to allow the timer server to send a time reply to the C4 CMTS.
Once SCM access is enabled, FTP from the front panel may not function.
Note: The following subnets are reserved for CMTS Internal Processor Communications (IPC) and will be rejected as invalid
destination IPs if you attempt to configure a route with them:
100.0.0.x 100.0.1.x 100.0.2.x
1.1.0.x 1.1.1.x