Chapter 46: Command Line Descriptions
STANDARD Revision 1.0 C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved. 2402
configure router bgp * neighbor * advertisement-interval
Configures the minimum route advertisement interval.
configure router bgp [<int>] neighbor <ipv6> advertisement-interval <0-600> [withdraw-interval <sec>]
configure router bgp [<int>] neighbor <ipv6> advertisement-interval [<0-600>] [withdraw-interval <sec>]
no
To remove an entry, use the no option.
Parameters
Autonomous System (AS) number. Valid range is 1-65535
[advertisement-
interval <sec>]
Value in seconds. Minimum interval between routing updates. Valid range is 0-600 seconds.
[withdraw-interval
<sec>]
Value in seconds. Allows a withdrawn to be sent more before the next update. Valid range is 0-600 seconds.