This setting makes the Current Playback follow the last Playback fader to be raised. If set to No then the
Current Playback is not changed when faders are raised - it is only changed when SELECT buttons are
pressed.
19.11.12 Wing Playbacks SEL+GO = BACK
This setting changes the function of SEL+GO on Playback Wings. By default SEL+GO reasserts the
Playback. This option enables SL+GO to be changed to be a BACK function on Wing Playbacks. This is
useful on Wing Playbacks that do not have physical BACK buttons.
19.11.13 Activate playback on start
This option enables one or more playbacks to be activated on start up. The options include:
None
PB1
Last Active
Wing 1 PB 1
Cue Stack 1
Macro 1
Lamp On All
When set to “Activate Playback PB” then when MagicQ starts PB1 is activated. This can then be used to
activate other playbacks and potentially run a complete show without user intervention.
When set to “Last active” then after a power up or a reset, MagicQ will reactivate Cue Stacks that were
running when the console was powered down or reset. MagicQ will start the Cue Stacks from the step that
they were previously on.
Note that all the options except for the PB1 option are only available on MagicQ consoles or on MagicQ
PC systems with MagicQ Wings or Interfaces attached.
19.11.14 Run in Execute Window
This setting starts the console / MagicQ PC up in the Execute Window.
19.12 Network Settings
19.12.1 IP Address
The console stores the TCP/IP address and subnet mask for the network interface. The addresses are stored as
part of the console configuration rather than as part of the show data. Thus erasing show data does not affect
their configuration.
For communicating with an Art-Net convertor the TCP/IP address must be set to a number in the range 2.x.x.x
(e.g. 2.9.200.1) and the Sub net address must be set to 255.0.0.0.
Note that on the MagicQ PC the TCP/IP address of the PC system is configured through Windows rather than
through the MagicQ PC software. However the MagicQ PC software must also be told the TCP/IP address so
that it knows which network interface to use.

Table of Contents

Other manuals for ChamSys MagicQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ChamSys MagicQ and is the answer not in the manual?

ChamSys MagicQ Specifications

General IconGeneral
TypeLighting Control Console
ManufacturerChamSys
SoftwareMagicQ
NetworkingYes
MIDI SupportYes
SMPTE SupportYes
Cues5000
Cue Stacks2000
EncodersVaries by model
TouchscreenYes
Universes64
Number of fixturesUnlimited (software dependent)
Network Ports4
DMX Outputs4
InputsMIDI, SMPTE
CompatibilityWindows, macOS, Linux (for software)
FeaturesPixel Mapping
FadersVaries by model (Mini Wing: 12, PC Wing: 10, MQ50: 12+12, MQ80: 10, MQ70: 10, MQ100 Pro: 10, MQ300 Pro: 15)