ChamSys Ltd www.chamsys.co.uk
MagicQ User Manual 179 Version 1.4.9.0
19.12.2 Subnet Mask
The sub net mask for the network interface.
For communicating with an Art-Net convertor the the Sub net address must be set to 255.0.0.0.
19.12.3 Send to applications on this PC
This setting is used to send Output data internally to other applications on the same PC. This can be used
to connect to a Visualiser or the MagicQ Media Centre on the same PC.
This setting is valid for PCs and Macs only – it is ignored on MagicQ consoles.
19.12.4 Ethernet remote protocol
Determines what protocol is used on the Ethernet communications. If set to “none” then any data received is
ignored. Data can be transmitted from the Macro field of Cue steps in the Cue Stack.
The other protocols are:
ChamSys Rem (rx)
ChamSys Rem (tx & rx)
ChamSys Rem (tx)
When using playback synchronisation between consoles this setting should be set to “ChamSys Rem (tx &
rx)”.
See
Ethernet Communications
and
Multiple Consoles
for more details.
19.12.5 Playback Sync Port
It is possible to configure the port used for synchronisation of playback between multiple MagicQ
consoles. The default port is 6553. If this port interferes with other equipment for any reason then it is
possible to change it.
19.12.6 Web Server
This is used to enable the in-built Web server which enables remote access to the console functions from
other euqipment using web browsers.
19.12.7 Web Server Port
The default web server port is 8080.
19.12.8 Multi Windows
This option is used to support multiple monitors on a MagicQ PC system or to connect a PC to a MagicQ
console to add additional monitor capability.