DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
271
Success.
DGS-1210-28MP/ME:5#
disable vlan_trunk
Purpose To disable VLAN Trunking on the switch.
Syntax
disable vlan_trunk
Description
The disable vlan_trunk command, along with the enable
vlan_trunk
command below, is used to disable and enable VLAN
Trunking on the Switch, without changing the VLAN Trunking
configuration on the ports.
Parameters None.
Restrictions Only administrator or operator-level users can issue this command.
Example usage:
To disable vlan_trunk on the switch:
DGS-1210-28MP/ME:5# disable vlan_trunk
Command: disable vlan_trunk
Success.
DGS-1210-28MP/ME:5#
show vlan_trunk
Purpose To display the current VLAN Trunking configuration on the Switch.
Syntax
show vlan_trunk
Description
The show vlan_trunk command display
s summary information
about VLAN trunking status and configured ports.
Parameters None.
Restrictions None.
Example usage:
To display the Switch’s current VLAN_trunk settings:
DGS-1210-28MP/ME:5# show vlan_trunk
Command: show vlan_trunk
VLAN Trunk Status :Enable
Member Ports :None
DGS-1210-28MP/ME:5#
Purpose To configure VLAN Trunking port settings on the Switch.
Syntax
config vlan_trunk ports [<portlist> | all] state [enable | disable]