DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
16
Mapping Status
Internal Power
Status
RPS Satus
RPS Power On
Disconnected Working
Internal Power & RPS Power On
Working Working
RPS No Power
Working Disconnected
When the devices are using the specific PSU (P/N SU54-21124-000S) with charger function, the internal power
and external power (battery) status were shown according to different mapping definitions below (Only for DGS-
1210-10/ME, DGS-1210-20/ME, DGS-1210-28/ME and DGS-1210-52/ME):
Mapping Status
Internal Power
Status
External Power
Satus (Battery)
No LEI Power Supply
Other Other
Battery Discharge Current OCP > 4.3A±0.1A
Disconnected Over Current
No AC In Use, Discharge, Battery Voltage < 11.6V±0.2V
Disconnected Low Voltage
No AC In Use, Discharge, Battery Voltage > 11.6V±0.2V
Disconnected Working
Battery Is Not Installed
Working Disconnected
AC In Use, Charging, Battery Voltage > 12.8V±0.2V
Working Connected
Battery Charging Current OCP > 1.0A±0.1A
Over Current Fail
AC In Use, Charging, Battery Voltage < 12.8V±0.2V
Working Low Voltage
NOTE: For the specific PSU (P/N SU54-21124-000S), it is optional 54W AC to
DC Power Supply Unit (PSU) with external lead-acid battery support that can be
used as a redundant power supply, or to connect an external 12V DC lead-acid
battery to charge the switch. The minimum required voltage for the lead-acid
battery is 12V DC, with a minimum capacity of 2 AH (Only for DGS-1210-
10/ME, DGS-1210-20/ME, DGS-1210-28/ME and DGS-1210-52/ME).
enable jumbo_frame
Purpose To enable jumbo frames on the device.
Syntax
enable jumbo_frame
Description
The enable jumbo_frame command enables jumbo frames on the
device.
Parameters None.
Restrictions Only Administrator or operate-level users can issue this command.
Jumbo frames will be enabled after save and restart.
Example usage:
To enable jumbo frames:
DGS-1210-28/ME:5# enable jumbo_frame
Command: enable jumbo_frame.
Success.
DES-1210-52/ME:5#