DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
15
Fan : OK
Current Temperature(Celsius) : 35
DGS-1210-28MP/ME:5#
NOTE: Only the following models support show environment command: DGS-
1210-28P/ME, DGS-1210-28MP/ME, DGS-1210-28X/ME, DGS-1210-28XS/ME,
DGS-1210-52/ME, DGS-1210-52P/ME, DGS-1210-52MP/ME and DGS-1210-
52MPP/ME.
show device_status
Purpose To display the device internal and external power status.
Syntax
show device_status
Description
The show device_status command displays the device internal and
external power status
which according to different mapping
definitions.
Parameters None.
Restrictions None.
Example usage:
To display the Switch internal and external power status:
DGS-1210-28/ME:5# show device_status
Command: show device_status
Internal Power(Main): Working
External Power(Backup): Disconnected
DGS-1210-28/ME:5#
NOTE: Only the following models Do Not support show device_status
command: DGS-1210-10P/ME, DGS-1210-28P/ME, DGS-1210-28MP/ME,
DGS-1210-52P/ME, DGS-1210/52MP/ME and DGS-1210-52MPP/ME.
For only DGS-1210-12TS/ME and DGS-1210-28X/ME, the internal power and RPS status were shown
according to two mapping definitions below:
Mapping Status
Internal Power
Status
RPS Satus
Internal Power Unknow & RPS Power On
- Working
RPS No Power
Working Disconnected
When the devices are using the specific PSU without charger function, the internal power and RPS status were
shown according to different mapping definitions below (Only for DGS-1210-10/ME, DGS-1210-20/ME, DGS-
1210-28/ME, DGS-1210-28XS/ME and DGS-1210-52/ME):