DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
56
Success.
config loopdetect
Purpose To configure the loop back detection interval time and recover time
on the Switch.
Syntax
config loopdetect interval_time <value 1-32767>
lbd_recover_time [0 | <value 60-1000000>]
Description
The config loopdetect command configures the loop back
detection interval time and recover time on the Switch.
Parameters
interval_time <value 1-32767> − Specifies the interval time of loop
back detection. The range is between 1 and 32767 seconds.
lbd_recover_time [0 | <value 60-10000>] − Specifies the recover
time of loop back detection on the switch. The range is between 60
and 10000 seconds.
Restrictions Only administrator-level users can issue this command.
Example usage:
To configure the loop back detection with interval time 500 on the Switch:
DGS-1210-28MP/ME:5# config loopdetect interval_time 500
Command: config loopdetect interval_time 500
Success.
show loopdetect
Purpose To display the loop back detection information on the Switch.
Syntax
show loopdetect {ports [<portlist> | all]}
Description
The show loopdetect command
displays the loop back detection
information on the Switch.
Parameters
<portlist> − A port or range of ports to be displayed.
all − All ports settings are to be displayed.
Restrictions None.
Example usage:
To display the loop back detection information on the Switch:
DGS-1210-28MP/ME:5# show loopdetect
Command: show loopdetect
Loopdetect Global Settings
--------------------------------------------
Loopdetect Status : Enabled
Loopdetect Mode : Port-Base