DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
343
44 3
DIGITAL DIAGNOSTIC MONITORING COMMANDS
The Digital Diagnostic Monitoring (DDM) commands in the Command Line Interface (CLI) are listed (along with
the appropriate parameters) in the following table.
config ddm ports
<portlist> [bias_current_threshold [high_alarm | low_alarm] | rx_power_threshold
| shutdown | state [enable | disable] | temperature_threshold |
tx_power_threshold | voltage_threshold]
config ddm power_unit [mw | dbm]
show ddm ports <portlist> [configuration | status | vendor_info]
Each command is listed in detail, as follows:
config ddm ports
Purpose To configure the DDM settings of the specified ports.
Syntax
config ddm ports <portlist> [bias_current_threshold
[high_alarm | low_alarm] | rx_power_threshold | shutdown |
state [enable | disable] | temperature_threshold |
tx_power_threshold | voltage_threshold]
Description
The config ddm ports command
is used to configure the DDM
settings of the specified ports.
Parameters
<portlist> - Specifies the range of ports to be configured.
bias_current_threshold - Specify the threshold of the optic module’s
bias current.
high_alarm -
Specify the high threshold for the alarm. When the
operating parameter rises above this value, the action associated
with the alarm is taken.
low_alarm -
Specify the low threshold for the alarm. When the
operating parameter falls below this value, the action associated
with the alarm is taken.
rx_power_threshold -
Specify the threshold of optic module’s
received power.
state - Specify the
DDM state to enable or disable. If the state is
disabled, no DDM action will take effect.
temperature_threshold - Specify the threshold of the optic module’s
temperature in centigrade. At least one parameter shall be specified
for this threshold.
shutdown -
Specify whether or not to shutdown the port when the
operating parameter exceeds the corresponding alarm threshold or
warning threshold. The default value is none.
tx_power_threshold -
Specify the threshold of the optic module’s
output power.
voltage_threshold - Specify the threshold of optic module’s voltage.
Restrictions Only Administrator or operator-level users can issue this command.
Example usage: