set spantree hello
8-18 Spanning Tree Configuration
Defaults
Ifsidisnotspecified,prioritywillberesetonSpanningTree0.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresetthebridgepriorityonSID1:
D2(su)->clear spantree priority 1
set spantree hello
Usethiscommandtosetthedevice’sSpanningTreehellotime,Thisisthetimeinterval(in
seconds)thedevicewilltransmitBPDUsindicatingitisactive.
Syntax
set spantree hello interval
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtogloballysettheSpanningTreehellotimeto10seconds:
D2(su)->set spantree hello 10
clear spantree hello
UsethiscommandtoresettheSpanningTreehellotimetothedefaultvalueof2seconds.
Syntax
clear spantree hello
Parameters
None.
Defaults
None.
interval Specifiesthenumberofsecondsthesystemwaitsbeforebroadcastinga
bridgehellomessage(amu lticastmessageindicatingthatthe systemis
active).Validvaluesare1‐10.