set pwa initialize
17-70 Security Configuration
Usage
PWAwilluseaguestpasswordandguestusernametograntnetworkaccesswithdefaultpolicy
privilegestouserswithoutestablishedloginnamesandpasswords.
Example
ThisexampleshowshowtoenablePWAguestnetworkingwithRADIUSauthentication:
D2(su)->set pwa guestnetworking authradius
set pwa initialize
UsethiscommandtoinitializeaPWAporttoitsdefaultunauthenticatedstate.
Syntax
set pwa initialize [port-string]
Parameters
Defaults
Ifportstringisnotspecified,allportswillbeinitialized.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoinitializeportsge.1.57:
D2(su)->set pwa initialize ge.1.5-7
set pwa quietperiod
Usethiscommandtosettheamountoftimeaportwillremainintheheldstateafterauser
unsuccessfullyattemptstologontothenetwork.
Syntax
set pwa quietperiod time [port-string]
Parameters
portstring (Optional)Initializesspecificport(s).Foradetaileddescriptionofpossible
portstringvalues,refertoPortStringSyntaxUsedintheCLIon
page 61.
time Specifiesquiettimeinseconds.
portstring (Optional)Setsthequietperiodforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 61.