show port inlinepower
Enterasys D-Series CLI Reference 4-3
Example
Thisexampleshowshowtoenableinlinepowertrapmessagingonmodule1:
D2(su)->set inlinepower trap enable 1
show port inlinepower
UsethiscommandtodisplayallportssupportingPoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
Ifnotspecified,informationforallPoEportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPoEinformationforportfe.2.1.Inthiscase,theport’s
administrativestate,PoEpriorityandclass havenotbeenchangedfromdefaultvalues:
D2(su)->show port inlinepower fe.2.1
Port Type Admin Oper Priority Class Power(W)
---- ---- ----- ---- -------- ----- --------
fe.2.1 wireless auto searching low 0 15.4
set port inlinepower
UsethiscommandtoconfigurePoEparametersononeormoreports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
Defaults
None.
portstring (Optional)DisplaysinformationforspecificPoEport(s).
portstring Specifiestheport(s)onwhichtoconfigurePoE.
adminoff|auto SetsthePoEadministrativestatetooff(disabled)orauto(on).
prioritycritical|
high|low
Setstheport(s)priorityforthePoEallocationalgorithmtocritical
(highest),highorlow.
typetype Specifiesastringdescribingthetype
ofdeviceconnectedtoaport.