set sntp poll-timeout
14-32 Logging and Network Management
set sntp poll-timeout
Usethiscommandtosetthepolltimeout(inseconds)foraresponsetoaunicastSNTPrequest.
Syntax
set sntp poll-timeout timeout
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheSNTPpolltimeoutto10seconds:
D2(su)->set sntp poll-timeout 10
clear sntp poll-timeout
UsethiscommandtocleartheSNTPpolltimeout.
Syntax
clear sntp poll-timeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtocleartheSNTPpolltimeout:
D2(su)->clear sntp poll-timeout
set timezone
UsethiscommandtoconfigurethecurrenttimezoneasanoffsetfromUTC.
Syntax
set timezone name [hours] [minutes]
timeout Specifiesthepolltimeoutinseconds.Validvaluesare1to30.