Alarm Group Commands
Enterasys D-Series CLI Reference 15-9
Alarm Group Commands
Purpose
Todisplay,configure,andclearRMONalarmentriesandproperties.
Commands
show rmon alarm
UsethiscommandtodisplayRMONalarmentries.TheRMONalarmgroupperiodicallytakes
statisticalsamplesfromRMONvariablesandcomparesthemwithpreviouslyconfigured
thresholds.IfthemonitoredvariablecrossesathresholdanRMONeventisgenerated.
Syntax
show rmon alarm [index]
Parameters
Defaults
Ifindexisnotspecified,informationaboutallRMONalarmentrieswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayRMONalarmentry3:
D2(rw)->show rmon alarm 3
Index 3
---------------------
Owner = Manager
Status = valid
Variable = 1.3.6.1.4.1.5624.1.2.29.1.2.1.0
Sample Type = delta Startup Alarm = rising
Interval = 30 Value = 0
Rising Threshold = 1 Falling Threshold = 0
Rising Event Index = 2 Falling Event Index = 0
Table 1540providesanexplanationofthecommandoutput.
For information about... Refer to page...
show rmon alarm 15-9
set rmon alarm properties 15-10
set rmon alarm status 15-11
clear rmon alarm 15-12
index (Optional)DisplaysRMONalarmentriesforaspecificentryindexID.