clear cos settings
11-22 Policy Classification Configuration
•ToS
Thisvaluecanbesetperclassofservice,butisnotrequired.Whenaframeisassignedtoa
classofserviceforwhichthisvalueisconfigured,theToSfieldoftheincomingIPpacketwill
beoverwrittentotheuserdefinedvalue.Allbutthelasttwo
bitsoftheToSfieldare
rewritable.ToScanbesetforCoSindexes0through7.
•IRLReference
TheCoSIRLreferencefieldisoptional,asratelimitsarenotrequired.TheIRLreferencedoes
notassignaninboundratelimitbutpointstotheCoSIRLReferenceMappingTable.This
referencemaybethoughtofasthevirtualratelimiterthatwillassignthephysicalratelimiter
definedbytheIRLReferenceMappingTable.
Example
ThisexampleshowshowtocreateCoSentry8withapriorityvalueof3:
D2(rw)->set cos settings 8 priority 3
clear cos settings
UsethiscommandtoclearClassofServiceentrysettings.
Syntax
clear cos settings cos-list {[all] | [priority] [tos-value] [irl-reference]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearthepriorityforCoSentry8:
D2(rw)->clear cos settings 8 priority
show cos settings
UsethiscommandtodisplayClassofServiceparameters.
Syntax
show cos settings [cos-list]
coslist SpecifiesaClassofServiceentrytoclear.
all Clearsallsettingsassociatedwiththisentry.
priority Clearsthepriorityvalueassociatedwiththisentry.
tosvalue ClearstheTypeofServicevalueassociatedwiththisentry.
irlreference CleartheIRLreferenceassociatedwiththisentry.