show system
Enterasys D-Series CLI Reference 2-13
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaysysteminformation:
D2(su)->show system
System contact:
System location:
System name:
PWR1-A Status PWR1-B Status
---------- ----------
Ok Not Installed and/or Not Operating
PWR2-A Status PWR2-B Status
---------- ----------
Not Installed and/or Not Operating Not Installed and/or Not Operating
Fan1-Status Fan2-Status
----------- -----------
Not Installed and/or Not Operating Not Installed and/or Not Operating
Uptime d,h:m:s Logout
-------------- -------
2,20:23:11 30 min
Thefollowingtableprovidesanexplanationofthecommandoutput.
Table 2-4 show system Output Details
Output What It Displays...
System contact Contact person for the system. Default of a blank string can be changed with the
set system contact command (“set system contact” on page 2-24).
System location Where the system is located. Default of a blank string can be changed with the
set system location command (“set system location” on page 2-24).
System name Name identifying the system. Default of a blank string can be changed with the
set system name command (“set system name” on page 2-23).
PWR1-A Status Operational status for the power supply connected to PWR1-A on the switch.
PWR1-B Status Operational status for the power supply connected to PWR1-B on the switch.
PWR2-A Status Operational status for the power supply connected to PWR2-A on the switch.
PWR2-B Status Operational status for the power supply connected to PWR1-B on the switch.
Fanx-Status Operational status of the fan(s). (This output not in use for the D2.)
Uptime d,h:m:s System uptime.
Logout Time an idle console or Telnet CLI session will remain connected before timing
out. Default of 5 minutes can be changed with the set logout command (“set
logout” on page 2-27).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys D-Series and is the answer not in the manual?

Enterasys D-Series Specifications

General IconGeneral
BrandEnterasys
ModelD-Series
CategorySwitch
LanguageEnglish

Related product manuals