EasyManua.ls Logo

Icom VE-PG3 - Page 117

Icom VE-PG3
347 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
BRIDGE MODE SETTING SCREEN
5-55
7. [Bridge Connection] Menu
M Bridge Connection Point (continued)
[Bridge Connection]–[Bridge Connection]
t My Station Port Number Enter the port number to receive the audio signal.
• This port number is also for the audio transmit port.
Setting range: Even numbers between 2 and 65534
(Some numbers may not be acceptable.)
The set port number (RTP) and the port number +1 (RTCP) are used for the
communication.
When using in the Unicast mode, do not set the port number which is
already used by another connection setting.
The default number differs, depending on the setting.
(Default: When [IP Communication Mode] is set to [Unicast]:
21500 (Transceiver 1 (TRX1)),
21502 (Transceiver 2 (TRX2)),
21504 (Digital Transceiver 1 (D-TRX1)),
21506 (Digital Transceiver 2 (D-TRX2)),
21508 (Digital Transceiver 3 (D-TRX3)),
21510 (Digital Transceiver 4 (D-TRX4)),
21512 (External Input1 (EXT1), External I/O 1 (EXT1)),
21514 (External Output1 (EXT1)),
21516 (External Input2 (EXT2), External I/O 2 (EXT2)),
21518 (External Output2 (EXT2)),
21540 (Controller 1),
21542 (Controller 2),
21544 (Controller 3),
21546 (Controller 4),
21520 (Emergency Notice),
When [IP Communication Mode] is set to [Multicast]:
22510 (Transceiver 1 (TRX1), Transceiver 2 (TRX2), Digital
Transceiver 1 (D-TRX1), Digital Transceiver 2 (D-TRX2), Digital
Transceiver 3 (D-TRX3), Digital Transceiver 4 (D-TRX4),
External Input1 (EXT1), External Output1 (EXT1), External I/O 1 (EXT1),
External Input2 (EXT2), External Output2 (EXT2), External I/O 2 (EXT2)),
Controller 1–Controller 4,
22520 (Emergency Notice).