EasyManua.ls Logo

Intel 6 SERIES CHIPSET - DATASHEET 01-2011 - Page 803

Intel 6 SERIES CHIPSET - DATASHEET 01-2011
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Datasheet 803
High Precision Event Timer Registers
20.1.5 TIMn_CONF—Timer n Configuration and Capabilities
Register
Address Offset: Timer 0: 100–107h, Attribute: RO, R/W
Timer 1: 120–127h,
Timer 2: 140–147h,
Timer 3: 160–167h,
Timer 4: 180–187h,
Timer 5: 1A0–1A7h,
Timer 6: 1C0–1C7h,
Timer 7: 1E0–1E7h,
Default Value: N/A Size: 64 bit
Note: The letter n can be 0, 1, 2, 3, 4, 5, 6, or 7 referring to Timer 0, 1, 2, 3, 4, 5, 6, or 7.
Bit Description
63:56 Reserved. These bits will return 0 when read.
55:52,
43
Timer Interrupt Rout Capability (TIMERn_INT_ROUT_CAP) — RO.
Timer 0, 1:Bits 52, 53, 54, and 55 in this field (corresponding to IRQ 20, 21, 22, and
23) have a value of 1. Writes will have no effect.
Timer 2:Bits 43, 52, 53, 54, and 55 in this field (corresponding to IRQ 11, 20, 21, 22,
and 23) have a value of 1. Writes will have no effect.
Timer 3:Bits 44, 52, 53, 54, and 55 in this field (corresponding to IRQ 11, 20, 21, 22,
and 23) have a value of 1. Writes will have no effect.
Timer 4, 5, 6, 7:This field is always 0 as interrupts from these timers can only be
delivered using direct processor interrupt messages.
NOTE: If IRQ 11 is used for HPET #2, software should ensure IRQ 11 is not shared
with any other devices to ensure the proper operation of HPET #2.
NOTE: If IRQ 12 is used for HPET #3, software should ensure IRQ 12 is not shared
with any other devices to ensure the proper operation of HPET #3.
51:45,
42:16
Reserved. These bits return 0 when read.
15
Timer n Processor Message Interrupt Delivery (Tn_PROCMSG_INT_DEL_CAP) — RO.
This bit is always read as ‘1’, since the PCH HPET implementation supports the direct
processor interrupt delivery.
14
Timer n Processor Message Interrupt Enable (Tn_PROCMSG_EN_CNF) — R/W
/ RO. If the Tn_PROCMSG_INT_DEL_CAP bit is set for this timer, then the software
can set the Tn_PROCMSG_EN_CNF bit to force the interrupts to be delivered directly
as processor messages, rather than using the 8259 or I/O (x) APIC. In this case, the
Tn_INT_ROUT_CNF field in this register will be ignored. The Tn_PROCMSG_ROUT
register will be used instead.
Timer 0, 1, 2, 3 Specific: This bit is a read/write bit.
Timer 4, 5, 6, 7 Specific: This bit is always Read Only ‘1’ as interrupt from these
timers can only be delivered using direct processor interrupt messages.

Table of Contents

Related product manuals