1076 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:SPI:CLOCk:SLOPe
(see page 1610)
Command Syntax
:SBUS<n>:SPI:CLOCk:SLOPe <slope>
<slope> ::= {NEGative | POSitive}
The :SBUS<n>:SPI:CLOCk:SLOPe command specifies the rising edge (POSitive) or
falling edge (NEGative) of the SPI clock source that will clock in the data.
Query Syntax
:SBUS<n>:SPI:CLOCk:SLOPe?
The :SBUS<n>:SPI:CLOCk:SLOPe? query returns the current SPI clock source
slope.
Return Format
<slope><NL>
<slope> ::= {NEG | POS}
See Also • "Introduction to :TRIGger Commands" on page 1295
• ":SBUS<n>:SPI:CLOCk:TIMeout" on page 1077
• ":SBUS<n>:SPI:SOURce:CLOCk" on page 1080