686 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
26 :POWer Commands
:POWer:SIGNals:DURation:ONOFf:OFF
(see page 1428)
Command Syntax
:POWer:SIGNals:DURation:ONOFf:OFF <value>[suffix]
<value> ::= value in NR3 format
[suffix] ::= {s | ms | us | ns}
The :POWer:SIGNals:DURation:ONOFf:OFF command specifies the duration of the
turn off analysis.
Query Syntax
:POWer:SIGNals:DURation:ONOFf:OFF?
The :POWer:SIGNals:DURation:ONOFf:OFF query returns the set duration time
value.
Return Format
<value><NL>
<value> ::= value in NR3 format
See Also ":POWer:ONOFf:APPLy" on page 661
":POWer:SIGNals:AUTosetup" on page 681
":POWer:SIGNals:IEXPected" on page 690
":POWer:SIGNals:OVERshoot" on page 691
":POWer:SIGNals:VMAXimum:ONOFf:OFF" on page 693
":POWer:SIGNals:VSTeady:ONOFf:OFF" on page 695
":POWer:SIGNals:SOURce:CURRent<i>" on page 698
":POWer:SIGNals:SOURce:VOLTage<i>" on page 699