:SBUS<n> Commands 29
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 769
:SBUS<n>:A429:SOURce
(see page 1428)
Command Syntax
:SBUS<n>:A429:SOURce <source>
<source> ::= {CHANnel<n>}
<n> ::= 1 to (# analog channels) in NR1 format
The :SBUS<n>:A429:SOURce command sets the source of the ARINC 429 signal.
Query Syntax
:SBUS<n>:A429:SOURce?
The :SBUS<n>:A429:SOURce? query returns the currently set source of the ARINC
429 signal.
Use the :TRIGger:LEVel:HIGH and :TRIGger:LEVel:LOW commands to set the
threshold levels for the selected source.
Return Format
<source><NL>
See Also ":TRIGger:LEVel:HIGH" on page 1146
":TRIGger:LEVel:LOW" on page 1147
":TRIGger:MODE" on page 1148
":SBUS<n>:MODE" on page 759
":SBUS<n>:A429:TRIGger:TYPE" on page 776
":SBUS<n>:A429:SIGNal" on page 768
":SBUS<n>:A429:SPEed" on page 770
":SBUS<n>:A429:FORMat" on page 767
"Introduction to :TRIGger Commands" on page 1139