860 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:I2S:TWIDth
(see page 1428)
Command Syntax
:SBUS<n>:I2S:TWIDth <word_size>
<word_size> ::= 4-32 in NR1 format
The :SBUS<n>:I2S:TWIDth command sets the width of the transmitted data word
in I2S anywhere from 4 bits to 32 bits.
Query Syntax
:SBUS<n>:I2S:TWIDth?
The :SBUS<n>:I2S:TWIDth? query returns the currently set I2S transmitted data
word width.
Return Format
<word_size><NL>
<word_size> ::= 4-32 in NR1 format
See Also "Introduction to :TRIGger Commands" on page 1139