842 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:FLEXray:TRIGger:FRAMe:TYPE
(see page 1428)
Command Syntax
:SBUS<n>:FLEXray:TRIGger:FRAMe:TYPE <frame_type>
<frame_type> ::= {NORMal | STARtup | NULL | SYNC | NSTArtup | NNULl |
NSYNc | ALL}
The :SBUS<n>:FLEXray:TRIGger:FRAMe:TYPE command sets the FlexRay frame
type to trigger on. The frame type setting is only valid when the FlexRay trigger
mode is set to FRAME.
NORMal — will trigger on only normal (NSTArtup & NNULl & NSYNc) frames.
STARtup — will trigger on only startup frames.
NULL — will trigger on only null frames.
SYNC — will trigger on only sync frames.
NSTArtup — will trigger on frames other than startup frames.
NNULl — will trigger on frames other than null frames.
NSYNc — will trigger on frames other than sync frames.
ALL — will trigger on all FlexRay frame types.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:FRAMe:TYPE?
The :SBUS<n>:FLEXray:TRIGger:FRAMe:TYPE? query returns the current frame
type setting for the FlexRay frame trigger setup.
Return Format
<frame_type><NL>
<frame_type> ::= {NORM | STAR | NULL | SYNC | NSTA | NNUL |
NSYN | ALL}
See Also "Introduction to :TRIGger Commands" on page 1139