EasyManua.ls Logo

Keysight Technologies InfiniiVision MSO-X 4154A

Keysight Technologies InfiniiVision MSO-X 4154A
1580 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:SBUS<n> Commands 29
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 889
:SBUS<n>:LIN:TRIGger:SYMBolic:VALue
(see page 1428)
Command Syntax
:SBUS<n>:LIN:TRIGger:SYMBolic:VALue <data>
<data> ::= value in NR3 format
The :SBUS<n>:LIN:TRIGger:SYMBolic:VALue command specifies the signal value
to trigger on when LIN symbolic data has been loaded (recalled) into the
oscilloscope and the LIN trigger mode is set to FSIGnal.
Query Syntax
:SBUS<n>:LIN:TRIGger:SYMBolic:VALue?
The :SBUS<n>:LIN:TRIGger:SYMBolic:VALue? query returns the specified signal
value.
Return Format
<data><NL>
<data> ::= value in NR3 format
See Also ":RECall:LDF[:STARt]" on page 718
":SBUS<n>:LIN:TRIGger" on page 881
":SBUS<n>:LIN:TRIGger:SYMBolic:FRAMe" on page 887
":SBUS<n>:LIN:TRIGger:SYMBolic:SIGNal" on page 888
NOTE
Encoded signal values are not supported in the remote interface (even though they can be
used in the front panel graphical interface).

Table of Contents

Related product manuals