EasyManuals Logo

Panasonic FP7 Series Command Reference Manual

Panasonic FP7 Series
1222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1013 background imageLoading...
Page #1013 background image
Subject automatically generated (Japanese) Subject automatically generated (English)
PLC status change (Prog > Run) PLC status change (Prog > Run)
PLC status change (Run > Prog) PLC status change (Run > Prog)
PLC status change (Operation stop error) PLC status change (Operation stop error)
PLC status change (Operation continuous error) PLC status change (Operation continuous error)
PLC status change (Error release) PLC status change (Error release)
SMTPcREQ command SMTPcREQ command
(Note 1) When multiple "PLC status change" settings have been specified as send triggers, the subject
automatically generated is the PLC status change that is actually detected.
(Note 2) The language used for subjects automatically generated is specified in the mail server setting.
Setting example
Exam
ple 1
S2 "GRPNO=0,SUBJECT=Time Notify Mail"
Settings Destination group number: 0, Subject: User-specified subject "Time Notify Mail"
Exam
ple 2
S2 "GRPNO=1+3+4+7,SUBJECT= Cyclic Notify Mail"
Settings Destination group numbers: 1, 3, 4, 7, Subject: User-specified subject "Cyclic Notify Mail"
Exam
ple 3
S2 "GRPNO=0+1+2+3+4+5+6+7,SUBJECTAUTO"
Settings Destination group numbers: 0 to 7, Subject: Automatically generated
Operand [S3] setting
Specify the starting address of the device area that stores the string data that indicates the
setting of the text of the mail to be sent, or a character constant.
Setting
item
Settings
S3
Mail text
Specify the starting address of the device area that stores the setting of the text
of the mail to be sent, or a character constant.
Character
count
(counted as
one-byte
characters)
Maximum 4096 characters for CPU units Ver.4.1 or later, and Ver.3.4 to Ver.3.x.
Maximum 256 characters for CPU units that are other than the above.
Operand [S4] setting
Specify the starting address of the device area that stores the string data that indicates the
text auto addition setting and the attached data specification of the mail to be sent, or a
character constant.
Setting
item
Settings
S4
Event mail
setting
Specify whether to add event transfer information after a mail text specified by
user or not.
INFO=NON: Not add automatically.
INFO=ADD: Add automatically.
17.24 SMTPcSET (Mail Transmission Setting)
WUME-FP7CPUPGR-12 17-125

Table of Contents

Other manuals for Panasonic FP7 Series