Exam
ple 12
S1 "ID=11,TRIG=STATUS,ERR>RUN"
Settings
Setting number: 11, Send trigger: PLC status change (When operation continue self-diagnostic
error is detected.)
Exam
ple 13
S1 "ID=12,TRIG=STATUS,ERRCLR"
Settings Setting number: 12, Send trigger: PLC status change (When error is cleared.)
Exam
ple 14
S1 "ID=13,TRIG=STATUS,ERR>STOP,ERR>RUN,ERRCLR"
Settings
Setting number: 13, Send trigger: PLC status change (When operation stop self-diagnostic error is
detected.), PLC status change (When operation continue self-diagnostic error is detected.), PLC
status change (When error is cleared.)
Operand [S2] setting
Specify the starting address of the device area that stores the string data that indicates the
destination group number (string) and the subject of the mail to be sent, or a character
constant.
Setting
item
Settings
Setting
range
S2
Destination group
number
Specify a destination group. Specify a destination group number
for the keyword "GRPNO=".
GRPNO=n1+n2 ... +n8
* Up to eight different group numbers connected with pluses (+)
can be selected at the same time.
0 to 7
Subject
Specify a mail subject.
User-specified subject: SUBJECT=xxxxx
Automatically-generated subject: SUBJECTAUTO
* For details of subjects generated automatically, refer to ""Subjects
automatically generated"".
(Note 1) Input each setting parameter separated by a comma ",".
(Note 2) Each parameter cannot be omitted. Specify them in the order of the above table. The order of
keywords cannot be changed.
(Note 3) Upper and lower case characters can be used for specifying keywords.
(Note 4) Up to 100 destinations can be set.
Subjects automatically generated
Subject automatically generated (Japanese) Subject automatically generated (English)
bit on detect (R100) bit on detect (R100)
Interval mail (1minute) Interval mail (1minute)
Interval mail (24hour) Interval mail (24hour)
Specified Time (Every Minute 0s) Specified Time (Every Minute 0s)
Specified Time (Every Hour 0m0s) Specified Time (Every Hour 0m0s)
Specified Time (Every Day 17h30m0s) Specified Time (Every Day 17h30m0s)
Specified Time (Every Friday 17h30m00s) Specified Time (Every Friday 17h30m00s)
PLC status change (Power On) PLC status change (Power On)
17.24 SMTPcSET (Mail Transmission Setting)
17-124 WUME-FP7CPUPGR-12

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals