Program example
SR14
DT100EIPMSATT
DF
R1
X6B
UNITSEL U100 U1
CIPMSET DT500DT200 U5
1st scan
OFF
EIP
preparation
done flag
DT500EIPMBODY
R1
SET
R1
EIPMSEND DT1000 DT2000
R1
RST
DT2000=0
Processing when transmission is
completed successfully
EIPMSEND
execution relay
Flag operations
Name Description
SR7
SR8
(ER)
To be set when the unit specified by UNITSEL is not an Ethernet unit.
To be set when the EtherNet/IP function is set to Not Use in the Ethernet unit configuration.
To be set in case of out-of-range in indirect access (index modification).
Set when executed in an interrupt program.
To be set when 253-word device cannot be assured from the device address specified by
[D1].
To be set when 3-word device cannot be assured from the device of D2.
17.32 EIPMSEND (EIP Message Send)