Operation unit Minimum value Maximum value
US 0.00 65535.99
SS -32768.00 32767.99
UL 0.00 4294967295.99
SL -2147483648.00 2147483647.99
Processing
Example 1) Unsigned 16 bits (US) (positive value)
[S]…DT10 [D]…DT0
[i]…US
* Operation error occurs if an unsigned integer is specified for the operation unit and
a negative value is converted.
Example 2) Unsigned 16 bits (US) (negative value)
[S]…DT10 [D]…DT0
[i]…US
Example 3) Signed 16 bits (SS) (positive value)
[S]…DT10 [D]…DT0
[i]…SS
Example 4) Signed 16 bits (SS) (negative value)
[S]…DT10 [D]…DT0
[i]…SS
DT10DT11
DT12DT13
DT14DT15
DT0
DT1
DT2
Example 5) Unsigned 32 bits (UL) (positive value)
[S]…DT10 [D]…DT0
[i]…UL
DT0DT1
DT2DT3
DT4
DT5
U 0
U 0
U 123456
K 0
K 0
K -234
K0
K0
K 234
U 0
U 0
U 0
U 0
U 0
U 234
SF 3.456780E02
SF 4.567890E02
SF 2.345670E
02
SF -3.456780E02
SF -4.567890E02
SF -2.345670E
02
SF 3.456780E02
SF 4.567890E02
SF 2.345670E
02
SF -3.456780E02
SF -4.567890E02
SF -2.345670E
02
SF 2.468000E02
SF 1.357000E
02
SF 1.234567E
05
DT10DT11
DT12DT13
DT14DT15
DT10DT11
DT12DT13
DT14DT15
DT10DT11
DT12DT13
DT14DT15
DT10DT11
DT12DT13
DT14
DT15
DT0
DT1
DT2
DT0
DT1
DT2
DT0
DT1
DT2
11.30 FIX (Conversion: Floating Point Real Number Data → Integer (Round
Decimal Digits))
WUME-FP7CPUPGR-12 11-69

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals