Program example
X100
Operation enabled
condition
Ready
positioning
X104
Tool
operation
X160
1st axis error
R10
R2
Positioning
control start
POSSET U1 U1
Specify slot
number, axis
number, and table
number.
R2
Positioning
control start
R10
Operation
enabled flag
X118
1st axis
BUSY
Y110
Operation
enabled flag
Positioning
start for 1st
axis
Positioning start-up
U1
Slot
number
Axis
number
Table
number
( )DF
( )DF
Flag operations
Name Description
SR7
SR8
(ER)
To be set in the case of out-of-range in indirect access (index modification).
To be set when the slot number and/or the axis number is out of the available range.
13.12 POSSET (Setting of Positioning Starting Table)