(a) Area in which the string to be taken out is stored (b)
Area in which the string that is taken out is
stored
(1) Storage area size (2) Character count
Precautions for programming
When the number of characters of [S3] is larger than the number of characters of the [S1]
string starting from the [S2] position, the transferal is performed for the number of characters
of [S1].
The [S2] position should be specified by a number counted from low order in sequence,
putting the least significant byte as K0 (Byte 0): 0, 1, 2 and so on.
When the number of characters in the operation result is larger than the storage area size of
[D], the transferal is performed for the storage area size of [D].
When specifying with a character constant, the maximum is 256 characters.
When specifying an empty string for [S1], the result is always 0.
Flag operations
Name Description
SR7
SR8
(ER)
To be set in the case of out-of-range in indirect access (index modification).
To be set when the destination range is outside the accessible range.
To be set when the number of characters for [S1] is smaller than or equal to [S2].
To be set when the number of characters is larger than the storage area size for [S1].
To be set when a data table with a storage area size of 0 or 65535 is specified.
SR9 (CY)
To be set when the number of characters taken out is larger than the storage area size of
[D].
14.35 EMIDR (Data Read from a Given Position in the String: With Storage
Area Size)
14-138 WUME-FP7CPUPGR-12