Code Name Description
5 Transfer disabled error
To be set when the transfer disable relay is "1=Transfer disabled" for the
transfer number that is specified during the execution of a transfer request
instruction.
6 Transfer canceled error
To be set when the transfer cancel request relay is changed from "0" to "1"
(the leading edge OFF to ON) which means a request to cancel.
7 Transfer failed error
To be set when the transfer done relay is "1=Transfer done" and the
transfer failure relay is "1=Transfer failed".
8
Data decompression
error (write)
To be set when an error occurs during decompression of data for
registration to a client.
9
Data decompression
error (read)
To be set when an error occurs during acquisition of data from a client.
10 File delete error
To be set when file deletion after transfer is specified but the file cannot be
deleted.
List of transfer done codes (FTP error codes)
Error code Description
226 Normal end
421
It is not possible to provide services. Ends control connection. At the time of the shutdown of
server.
425 It is not possible to open data connection.
426 Connection was closed and data transfer was canceled for some reason.
450 It is not possible to execute the request for any reason of access authority or file system.
451 Processing was canceled due to a local error.
452 It is not possible to execute due to any problem in disk capacity.
500 Syntax error of commands
501 Syntax error of arguments or parameters
502 Command is not implemented.
503 The order of using commands is wrong.
504 Arguments or parameters are not implemented.
530 User could not log in.
532 Charging information must be confirmed with ACCT command for file transmission.
550 It is not possible to execute the request for any reason of access authority or file system.
551 It is not possible to execute because of a problem in the type of page structure.
552 It is not possible to execute due to any problem in disk capacity.
553 it is not possible to execute due to an incorrect file name.
1XXX An error occurred during file deletion after transfer (not to be retried).
9XX Client service error
List of transfer done codes (HTTP error codes)
Error code Description
2XX Normal end
17.3 ETSTAT (Acquiring Ethernet Unit Information: FTP/HTTP/SMTP)
17-20 WUME-FP7CPUPGR-12

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals