62C-25
V1
MR-453-X79-62C000$060.mif
CLIMATE CONTROL
Fault finding – Conformity check
62C
SUB-FUNCTION: COLD LOOP (CONTINUED)
*AC: Air conditioning
NOTES
Only carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: Engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air conditioning
compressor not activated).
Note:
Read the parameters when the vehicle is cold (in the morning) to check the conformity
of the temperature parameters (without thermometer). The two temperatures should be
approximately equal (interior, exterior and engine coolant).
Computer
Parameter or Status
Checked or Action
Display and notes Fault finding
Injection
PR125: Power absorbed
by the AC* compressor
0 W (ambient tº = 23ºC)
If there is a fault, refer to
the interpretation of this
parameter.
ET298: Low-speed fan
assembly
INACTIVE
In the event of a fault, refer
to the interpretation of
this status.
ET299: High-speed fan
assembly
INACTIVE
In the event of a fault, refer
to the interpretation of
this status.
ET018: Air conditioning
request
INACTIVE / NO
In the event of a fault, refer
to the interpretation of
this status.