62C-29
V1
MR-453-X79-62C000$060.mif
CLIMATE CONTROL
Fault finding – Conformity check
62C
SUB-FUNCTION: COLD LOOP (CONTINUED)
NOTES
Only carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: Engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
Computer
Parameter or Status
Checked or Action
Display and notes Fault finding
Injection
ET298: Low-speed fan
assembly
ACTIVE if the refrigerant
pressure is less than
19 bar,
INACTIVE otherwise.
In the event of a fault, refer
to the interpretation of
this status.
ET299: High-speed fan
assembly
ACTIVE if the refrigerant
pressure is more than
19 bar,
INACTIVE otherwise.
In the event of a fault, refer
to the interpretation of
this status.
ET018: Air
conditioning request
ACTIVE / YES
In the event of a fault, refer
to the interpretation of
this status.