RFL 9300 RFL Electronics Inc.
September 5, 2007 xiii (973) 334-3100
Figure 21-1. RFL 93 Alarm I/O Module................................................................................................................................. 1
Figure 21-2. Controls and indicators, RFL 93 Alarm I/O Module.......................................................................................... 2
Figure 21-3. Component locator drawing, RFL 93 Alarm I/O Module, ................................................................................. 8
Figure 22-1. Front panel view of RFL 93 SH FIBER short haul interface module and RFL FSU fiber service unit............. 2
Figure 22-2. Controls and indicators, RFL 93 SHFI short haul fiber interface module.......................................................... 4
Figure 22-3. Typical Fiber Service Unit Installation............................................................................................................... 5
Figure 22-4. Component locator drawing, RFL 93 short haul fiber interface module (Assembly No. 107500) .................... 8
Figure 22-5. Schematic, RFL 93 Short Haul Fiber Module (3 sheets) (Assembly No. 107500; Schematic No. D-107504-C)
.......................................................................................................................................................................................... 9
Figure 23-1. RFL 93 G.703 Interface I/O Module.................................................................................................................. 1
Figure 23-2. Controls and indicators, RFL 93 G.703 Interface I/O Module........................................................................... 2
Figure 23-3. Setting J5 for Normal or Loops Operation ......................................................................................................... 4
Figure 23-4. Component locator drawing, RFL 93 G. 703 Interface I/O Module .................................................................. 8
Figure 23-5. Schematic, RFL 93 G.703 module (Assembly No. 106730; Drawing No. D-106734-B).................................. 9
Figure 24-1. Typical RFL 9300 Single Pole Chassis, front panel view .................................................................................. 1
Figure 24-2. Typical RFL 9300 Single Pole Chassis, front panel view showing LED indicators .......................................... 2
Figure 24-3. Typical RFL 9300 Single Pole Chassis, rear panel view.................................................................................... 3
Figure 24-4. Target Message Word sent from the Display Controller to the Single-Pole Chassis ......................................... 8
Figure 24-5. 16-bit Status messages transmitted by the Single-Pole logic to the Supervisor at 250ms intervals ................... 9
Figure 24-6. Component locator drawing, RFL 9300 single pole chassis, main circuit board ............................................. 13
Figure 24-7. Schematic, 9300 Single Pole Chassis (Drawing No. D-106714-B) Sheet 1 of 2 ............................................ 14
Figure 24-8. Component locator drawing, RFL 9300 single pole chassis, rear panel........................................................... 16
Figure 24-9. Schematic, 9300 Single Pole Chassis, Rear Panel (Drawing No. D-106709-C) .............................................. 17
Figure 25-1. Typical RFL 9300 chassis .................................................................................................................................. 1
Figure 25-2. Block diagram of RS-232 front board ................................................................................................................ 2
Figure 25-3. Component locator drawing, RFL 93 INTER Interconnect Motherboard.......................................................... 4
Figure 25-4. RFL 93 INTER Interconnect Motherboard (Assembly No. 103905-1; Schematic No. D-103909-1-D) ........... 5
Figure 25-5. Component locator drawing, RFL 9300 front panel RS-232 module ................................................................ 6
Figure 25-6. RS-232 Front Panel Interface (Assembly No. 106755; Schematic No. C-106759-B) ....................................... 7
Figure 26-1. Typical RFL 9300 Expansion Chassis, rear view............................................................................................... 1
Figure 26-2. Component locator drawing, RFL 9300 expansion chassis power supply (Assembly No. 106350).................. 2
Figure 26-3. Schematic, Power Converter I/O – 250 Vdc, For RFL 9300 Charge Comparison System................................ 3
Figure 27-1. Protocol converter block diagram....................................................................................................................... 4
Figure 29-1. RFL 9300 modem dependability versus S/N ratio (measured)........................................................................... 2
Figure 29-2. RFL 9300 probability of passing false words (theoretical) ................................................................................ 4
Figure 29-3. RFL 9300 modem security (theoretical)............................................................................................................. 5