SP1-xxx Feed
SM Appendix 2-27 D093/D094
Appendix:
SP Mode
Tables
21 Paper Interval: Step 1
When the pressure roller center and end thermistor detect a temperature in the
Step 1 range (SP1940 011), the setting of this SP is activated to set the length of
the interval between sheets in the paper path.
[1 to 10/1.4/0.1]
The default setting (1.4) is the variable for Step 1 multiplied by the constant set
for Step 1 of the machine:
D093: 480 mm. The default interval is 672 mm (1.4 x 480 mm).
D094: 168 mm. The default interval is 235 mm (1.4 x 168 mm).
Setting a smaller or larger number decreases or increases the length of the
interval with this simple calculation. This standard interval can be modified
slightly with SP1923.
22 Paper Interval Step 2
When the pressure roller center and end thermistor detect a temperature in the
Step 2 range (SP1940 012), the setting of this SP is activated to set the length of
the interval between sheets in the paper path.
[1 to 10/2.1/0.1]
The default setting (2.1) is the variable for Step 2 multiplied by the constant set
for Step 2 of the machine:
D093: 480 mm. The default interval is 1008 mm (2.1 x 480 mm).
D094: 168 mm. The default interval is 353 mm (2.1 x 168 mm).
Setting a smaller or larger number decreases or increases the length of the
interval with this simple calculation. This standard interval can be modified
slightly with SP1923.